Long Arched Parking Canopy

Long Arched Parking Canopy shows a long cream curved canopy on dark arches beside a glazed building entrance and steps. Connect a row of parking positions with the building frontage. The repeated arches create shade while keeping the outer edge open.

SKU: TS-IMG-261115-089 Category: Brand:

Description

Long Arched Parking Canopy

Long Arched Parking Canopy shows a long cream curved canopy on dark arches beside a glazed building entrance and steps. Connect a row of parking positions with the building frontage. The repeated arches create shade while keeping the outer edge open. Also, consider the view from the house and the approach together. Discuss these priorities before ordering.

Features and Benefits of This Arched Parking Shelter

Look at the complete arrangement rather than one decorative detail. The following features can guide a useful discussion about the proposed layout.

  • A curved roof gives the bay a clear outline and can complement both simple and traditional residential elevations.
  • Open sides leave the approach visible and give passengers more freedom to move when the support layout suits the vehicles.
  • A coordinated frame and covering can connect the parking area visually with the house, boundary and existing paving.
  • Planning the roof around the actual bay helps place shade over the vehicle instead of unused space beside it.

Design and Structural Considerations

Reserve access to entrance steps and the glazing maintenance route. Check that roof supports do not narrow a pedestrian path beside the parked vehicles.

An arch changes the roof profile, but useful parking space still depends on the supports below it. Therefore, compare the roof’s lowest edge with the required vehicle clearance. The curved appearance alone cannot establish structural capacity or the final drainage arrangement.

Check the repeated arches beside the building steps and glazing, preserving a clear walking route even while cars occupy the spaces immediately beside the entrance frontage.

Materials and Customization Options

Confirm the roof covering and dark frame finish. Plan runoff away from steps and glazing while retaining access to upper connections.

Treat colour, fabric performance and structural material as separate decisions. A pale covering does not identify its composition or tested protection. Instead, discuss the required shade, rain exposure and appearance with Tent Shed, then confirm the selected covering, protective finish and edge details in the written proposal.

Confirm the pale roof covering and dark frame finish together, including how the outer edge and building-side junction handle runoff above the pedestrian access and glazing below.

Suitable Applications in the UAE

The pictured arrangement provides a starting point for parking beside offices, villas or glazed reception buildings. This design direction suits a defined vehicle bay more naturally than a fully enclosed garage. For a home project, consider how the car enters and how people reach the door. Larger versions require their own support layout; repeating the appearance does not establish the engineering.

A reception frontage or large villa driveway can use the repeated roof where parked vehicles and visitors need a coordinated arrangement along the same building-side outdoor route.

Installation and Maintenance

Plan foundations and fixings for the actual site rather than assuming the paving provides a structural base. Also, reserve a practical work area during installation. Confirm drainage before closing roof edges or ceilings. For ongoing care, use the approved cleaning method, remove debris safely and arrange competent inspection when connections, panels or fabric show damage or movement.

Retain access for window cleaning as well as canopy inspection, and ensure roof maintenance equipment can reach the higher connections without relying on the entrance steps as a platform.

Request a Tent Shed Quotation

To discuss a quotation, send Tent Shed the design name and photographs of the actual space. Add your UAE location, approximate dimensions and intended use. Also, note any doors, services or landscaping that need to remain accessible. Ask for a written offer confirming the proposed construction, finish and installation scope for that site.

Additional information

Product Type

Car parking canopy

Design Style

Arched roof

Suitable Application

Parking beside offices, villas or glazed reception buildings

Size / Dimensions

Made to measure: length x width x clear height confirmed after site measurement. A 550 x 550 x 240 cm layout can be considered for compatible designs; larger, taller and multi-bay layouts require their own dimensions.

Frame / Steel Sections

Steel pipe option: main member 6 in diameter x 5 mm wall; truss member 2.5 in diameter x 3 mm wall. Steel tube alternatives; final sizes depend on span and structural design.

Roof / Infill Covering

PVC covering option: 900 g/m². HDPE shade-net option: fabric weight and shade characteristics confirmed for the selected product. Colour and covering selection confirmed in the quotation.

Accessories / Connections

Grade 8.8 bolts and anchor bolts where specified; galvanized nuts, connection plates and stiffeners to the approved connection design. Hardware quantities and sizes confirmed per project.

Footing / Fixing Method

Ground-supported option: 80 x 80 x 80 cm reinforced-concrete footing with four grade 8.8 anchor bolts, nominal 24 mm size. Final footing, anchor dimensions and embedment require site-specific engineering.

Fabric Warranty

10-year warranty on the selected eligible fabric covering only, subject to the written quotation and warranty terms. Frame, coating, fixings, panels, electrical items and operating mechanisms require separately agreed coverage.

Steel Finishing

Epoxy or marine-epoxy paint system for steel components where specified; surface preparation, coats, dry-film thickness and colour confirmed in the quotation.

Steel Quality

Fabricated steel components: hot-dip galvanizing to BS EN ISO 1461 where specified. Zinc to ASTM B6 where included in the galvanizing specification. Material grade and inspection scope confirmed per project.

Structural Design

Site-specific structural calculations and applicable UAE authority requirements. A 160 km/h design-wind basis may be specified where the engineer confirms suitability; it is not a universal tested rating for every design.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.